同心圆环区域电容层析成像传感器数目优化
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

TH81

基金项目:

科技部重大仪器专项(2018YFF01013801)资助


Optimization of the number of electrical capacitance tomography sensors with concentric annulus structure
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对同心圆环区域,设计了不同数目的组合电容层析成像传感器,以提高传感器在测量区域的空间分辨率。 基于数值 仿真,对内外径之比为 0. 2、0. 3、0. 4、0. 5 的 4 种同心圆环区域,采用了传统外层 12 电极和 12-4、12-6、12-8 3 种内外双层结构电 极(IEE),研究了其成像特性。 其中 IEE 传感器测量过程施行外部-对立-内部(EOI)和外部-对立(EO)两种激励策略,对几种典 型的介质分布进行测量,并采用 LBP、Tikhonov、Landweber 算法开展图像重建。 结合数值仿真和实验验证,结果显示内外双层电 极测量随着同心圆环形区域内外径比增大,内层电极数目存在最优值,12- 4 型电极结构在不同环形区域的重建图像质量和稳 定性更好。 采用 LBP 算法进行成像时,EOI 激励策略相比于 EO 激励策略在成像精度上略有优势;采用 Tikhonov 算法和 Landweber 迭代算法时,EO 激励策略能有效避免异常电容值的影响,与 IEE 电极组合时能在不同内外径比的同心圆环区域测量 中提高成像质量。

    Abstract:

    To improve the spatial resolution of ECT sensors in a concentric annulus measurement area, different number of combined electrodes ECT sensors are designed. For four types of concentric annulus area with inner and outer diameter ratios of 0. 2, 0. 3, 0. 4 and 0. 5, traditional 12 external electrodes (EE) and 12-4, 12-6, 12-8 internal-external electrodes (IEE) are considered. The IEE sensors are implemented with external-opposite-internal ( EOI) and external-opposite ( EO) measuring strategies. The capacitance between different electrode pairs is calculated for typical permittivity distributions by numerical simulation approach. The obtained capacitances are used to reconstruct images using LBP, Tikhonov, and Landweber algorithms, respectively. Based on numerical simulation and experimental investigation, the main results are given as follows. As the ratio of the inner and outer diameters of the concentric annulus area increases, there is an optimal number of inner electrodes which the quality of reconstructed images with the 12-4 electrodes structure are higher in the measurement. When LBP algorithm is used, the EOI excitation strategy has a slight advantage over the EO excitation strategy in imaging accuracy. When the Tikhonov algorithm and Landweber iterative algorithm are used, the EO excitation strategy can effectively reduce the influence of abnormal capacitance, and effectively improve the quality of reconstructed images when combined with IEE sensors in the measurement of concentric annulus areas with different inner and outer diameter ratios.

    参考文献
    相似文献
    引证文献
引用本文

刘再兴,王海刚.同心圆环区域电容层析成像传感器数目优化[J].仪器仪表学报,2021,(10):93-103

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-06-28
  • 出版日期:
文章二维码