    摘要:

    预应力钢绞线是混凝土结构的关键受力构件,其有效预应力一旦损失严重,将威胁结构安全。 为了精准监测钢绞线应 力状态,基于磁谐振原理和磁弹效应,提出预应力钢绞线磁谐振应力监测方法。 设计了双线圈磁谐振传感器,分析了测试频率 选择方法,搭建了钢绞线应力监测系统。 为验证该方法的可行性,对不同设计拉力的镀锌钢绞线和涂环氧树脂钢绞线试件进行 了应力监测试验。 试验结果表明:不同批次的钢绞线对应的感应电压随拉力的变化趋势相似;感应电压和钢绞线应力非线性相 关,三次拟合优度 R 2 均大于 0. 96,灵敏度可达 0. 064 79% / kN;依据拟合结果和测得感应电压计算钢绞线应力,得到在高荷载情 况下钢绞线应力测试误差集中小于 4% ,为预应力钢绞线监测提供了新方法。

    Abstract:

    Prestressed steel strands are key components of concrete structures. Once the prestress loses severely, the structure safety will be threatened. To precisely monitor the stress of the steel strand, a prestress monitoring method is proposed, which is based on the magnetic resonance and the magnetoelastic effect. A dual-coil magnetic resonating sensor is designed, the selection of the test frequency is analyzed, and a stress monitoring system is established. To evaluate the feasibility of this method, stress monitoring experiments are carried out. To be special, the galvanized steel strands and the epoxy-coated steel strands are tested under different design tensions. Experimental results show that the induced voltages change similarly with the tension under different batches of steel strands. The induced voltage nonlinearly is related to the stress. By using the three fit, the goodness of the fitting (R 2 ) is greater than 0. 96. In addition, the test sensitive reaches 0. 064 79% / kN. According to the fitting results and the measured induced voltage, the stress of the steel strand is calculated. When the tension is high, the test error is almost less than 4% . This demonstrated that a new stress monitoring method is proposed for prestressed steel strands.

    参考文献
    相似文献
    引证文献
引用本文

周建庭,刘惠玲,张森华,张 洪,廖 棱.预应力钢绞线磁谐振应力监测试验研究[J].仪器仪表学报,2022,43(2):108-116

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-02-06
  • 出版日期:
文章二维码