NO x 传感器的氧补偿及其标定策略
CSTR:
作者:
中图分类号:

TH89


Oxygen compensation of the NOx sensor and its calibration strategy
Author:
  • 摘要
  • | |
  • 访问统计
  • | |
  • 相似文献 [20]
  • | | |
  • 文章评论
    摘要:

    针对氧化锆基氮氧化物传感器信号受汽车尾气氧含量影响,导致精度不佳问题,提出一种氧补偿算法和标定策略。 根据 NOx 传感器工作原理进行模拟试验,分析不同氧含量下泵电流 IP2 与 NOx 浓度的关系,得出氧补偿算法,并分析了氧含量与补偿系 数的关系,设计出一种实时对 IP2 误差补偿的方案,使 IP2 在氧含量为 0% ~20% ,NOx 为 0~3 000×10 -6 范围内的误差减小到 23 nA, 对应 NOx 浓度误差降低到 15×10 -6 以内。 为进一步提高传感器测量的准确度,设计了一套标定方案,并与国外 NOx 传感器进行对 比测试。 结果表明,该传感器在发动机瞬态工况下,NOx 浓度为 0~2 000×10 -6 的环境中,测量误差为 0~25×10 -6 ,验证了该方案的 可行性,满足尾气中 NOx 浓度的监测要求,为提高氧化锆基 NOx 传感器精度提供了可靠的解决方法。

    Abstract:

    An oxygen compensation algorithm and calibration strategy are proposed to address the problem that the zirconia-based NOx sensor signal is affected by the oxygen content of vehicle exhaust, which may result in poor accuracy. A simulation test is conducted according to the working principle of the NOx sensor, the relationship between pump current IP2 and NOx concentration at different oxygen content is analyzed. The oxygen compensation algorithm is derived, and the relationship between oxygen content and compensation coefficient is analyzed. A real-time compensation scheme for IP2 error is designed. Consequently, the error of IP2 in the range of oxygen content from 0% ~ 20% and NOx from 0~ 3 000×10 -6 is reduced to 23 nA, and the Corresponding NOx concentration error is reduced to within 15×10 -6 . To further improve the accuracy of the sensor measurement, a calibration scheme is designed and tested in comparison with foreign NOx sensors. The results show that the sensor has a measurement error of 0~25×10 -6 in an environment with NOx concentration of 0~2 000×10 -6 under transient engine conditions, which verifies the feasibility of the scheme and well meets the requirements for monitoring NOx concentration in the exhaust gas, and provides a reliable solution for improving the accuracy of zirconia-based NOx sensors.

    参考文献
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

钱 枫,付海亮,王明达,王 超,祝 能. NO x 传感器的氧补偿及其标定策略[J].仪器仪表学报,2022,43(5):15-22

复制
分享
文章指标
  • 点击次数:1450
  • 下载次数: 1883
  • HTML阅读次数: 0
  • 引用次数: 0
历史
  • 在线发布日期: 2023-02-06
文章二维码